Polarization Cell
Polarization Cell
Product Code : 56
Product Description

Polarization Cell

Polarization cell protects against induced AC current and ground fault current on buried pipelines. Polarization cells permit low-level voltage of cathodic protection to uniform flow and prevent hazardous voltages. Polarization cell consist of multiple plates of steel arranged, fixed and immersed in 30% KOH (Potassium Hydroxide) solution.

Specially selected oil layer stop the evaporation of solution to some extend. It is advisable to verify the solution level periodically. Polarization cell is fitted in transparent body to check solution level. Normal storage of cell does not have any internal voltage and act as a grounding switch in presence of high voltage. Polarisation cell works on electrochemical principle. Installed plates with large surface area polarize and allow in developing safe DC voltage suitable for cathodic protection. As the voltage increases from DC or AC voltage, the polarisation film breaks and polarization cell conduct current. Specially designed polarization cells have properties to retain solution level to the maximum period with specially added floating oil.

Polarization cells control the flow of potentially dangerous AC and DC current in buried surface protected oil & gas, water pipelines on the buried metallic structures. Grounding cells needs to be installed with high precaution of gas ventilation. Improper installation could produce hazardous gases resulting to cause explosion and harmful to operators. The cells are safe while using as per the rated capacity given in the information section to prevent corrosion.

Technical Specifications

C-5A dimensions in mm

Height to top of lid

175

Width at bottom

115

Overall height

210

Width at top

134

Depth at bottom

115

Depth at top

134

Polarization cell models

Model

Rated capacity pass 1/2 sec faults

Pares of plates

Rated max. capacity Amp

Temp range

Empty weight

Weight with solution

C-5A

5000

5

30

0-60oC

2.3 Kg

5.1 Kg

C-25A

25000

12

175

0-60oC

32.8 Kg

41.0 Kg

C-50A

50000

25

350

0-60oC

42.0 Kg

85.0 Kg