About Soil Resistivity Meter SR-2 - Tinker & Rasor
Technical specification
- Resistivity Ranges: 0.01 Ohm to 3.3 MOhm
- Accuracy: 10%
- Operating Temperature: 0-50C (32-122F)
- Case: Pelican long-life case with weather-sealed lid
- Dimensions: 10.75 x 10.75 x 6.5 (273 x 273 x 165 mm)
- Operating Weight: 6 lbs
- Shipping Weight: 7 lbs
Precision and Reliability in Soil SurveysEngineered for geotechnical and environmental applications, the SR-2 delivers accurate soil resistivity readings between 0 and 2000 Ohms. The manual zero adjustment potentiometer and selectable current ranges allow users to tailor measurements for diverse site conditions, ensuring consistent and reliable field data every time.
User-Friendly Design and PortabilityThe lightweight, compact design makes the SR-2 exceptionally portable. With everything housed in a sturdy carrying case, including all necessary accessories, this meter is ideal for fieldwork. Its analog display is easy to read, and the four-terminal input guarantees secure electrode connections.
FAQs of Soil Resistivity Meter SR-2 - Tinker & Rasor:
Q: How do I use the Soil Resistivity Meter SR-2 for field measurements?
A: To use the SR-2, place the four electrodes in the soil following the Wenner Four-Pin Method as described in the manual. Connect the leads, adjust the zero using the potentiometer, select the desired range, and read the resistivity from the analog meter. Always ensure firm electrode connections for accurate results.
Q: What are the main benefits of using the SR-2 in soil resistivity testing?
A: The SR-2 offers high accuracy (1% of reading), durability with its high-impact plastic case, and portability. Its long battery life and included accessories make it convenient for field operations, while manual adjustments and built-in overload protection enable reliable and safe measurements.
Q: When is it appropriate to calibrate the SR-2, and how is it calibrated?
A: The SR-2 comes factory calibrated and ready for use. Routine calibration is not needed under regular usage conditions. If required, calibration should be performed by qualified personnel, following the procedures outlined in the operating manual.
Q: Where can the SR-2 be used, considering environmental conditions?
A: The SR-2 operates reliably in environments ranging from 0C to 50C and up to 85% relative humidity (non-condensing). Its rugged, portable design and protective case make it suitable for outdoor fieldwork, construction sites, and geotechnical investigations.
Q: What process does the SR-2 use for soil resistivity measurement?
A: The SR-2 employs the Wenner Four-Pin Method, where four equally spaced electrodes are inserted into the ground and connected to the meters four-terminal input. The device then measures resistivity based on the voltage and current detected across the electrodes.
Q: How should I maintain and store the SR-2 when not in use?
A: After use, clean the electrodes and store the SR-2 in its protective carrying case. Remove the batteries if storing for an extended period to prevent leakage. Regularly check the device and accessories for any signs of wear or damage.