Permanent Reference Cells - Fontana 103 Ag/agcl
Permanent Reference Cells - Fontana 103 Ag/agcl

Permanent Reference Cells - Fontana 103 Ag/agcl

Price 50 INR/ Unit

MOQ : 1 Unit

Permanent Reference Cells - Fontana 103 Ag/agcl Specification

  • Measurement Range
  • -1200 mV to +1200 mV
  • Equipment Type
  • Permanent Reference Cell
  • Sensor Type
  • Electrochemical
  • Capacity
  • Designed for continuous service in soil
  • Pressure Range
  • Atmospheric pressure
  • Temperature Range
  • -10°C to +60°C
  • Resolution
  • 1 mV
  • Connectivity Type
  • Copper lead wire connection
  • Humidity %
  • Up to 95%
  • Material
  • Silver/Silver Chloride element with high impact PVC body
  • Power Consumption
  • Passive device, negligible
  • Accuracy
  • ±10 mV
  • Range
  • -1200 mV to +1200 mV
  • Application
  • Long-term, permanent underground and submerged cathodic protection monitoring
  • Packaging
  • Individually boxed with instruction manual
  • Model Number
  • Fontana 103
  • Total Length
  • Approx. 350 mm
  • IP Rating
  • IP68 suitable for underground and underwater installation
  • External Diameter
  • Approx. 45 mm
  • Maintenance
  • Maintenance-free design
  • Weight
  • Approx. 1.4 kg
  • Installation Method
  • Direct burial/submersion in backfill or soil
  • Electrode Surface Area
  • Adjustable, typically 25 cm2
  • Electrolyte Type
  • Special formulated electrolyte with high ionic conductivity
  • Cable Length
  • Standard 5 meters (custom lengths available)
 

Permanent Reference Cells - Fontana 103 Ag/agcl Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Supply Ability
  • 500 Units Per Day
  • Delivery Time
  • 1 Days
  • Main Export Market(s)
  • Australia, North America, South America, Eastern Europe, Western Europe, Middle East, Central America, Asia, Africa
  • Main Domestic Market
  • All India
 

About Permanent Reference Cells - Fontana 103 Ag/agcl

Permanent Reference Cells - Fontana 103 Ag/agcl 

Silver Silver Chloride (Ag/AgCl) Reference Cell

Silver Silver Chloride sea water / marine service reference cell is the regular immersion reference electrode to measure electrical potentials for corrosion engineers. It is used asr permanent fresh water service electrode. These electrodes has specialty to retain and quick drain of water to show uninterrupted and accurate results all the time. The silver / silver chloride reference electrode is a widely used reference electrode because it is simple, very stable and non-toxic. It is mainly used in seawate, river water and high water content soils, mudy water.

Features

Rugged ultraviolet and chemically resistant inert ceramic tubing. Continuous moisture retaining shelf capability with preheated uniform, controlled ceramic porosity. Especially gel surrounding with silver- silver chloride wire reduces electrical resistance and no requirement of moistening. Excellent life and highest sensing area allows measurements with stability.

Long Life
Designed long life reference cell.

Applications
Direct silver chloride reference cell in sea water, fresh water, brackish water, marine and offshore with or without chlorides are supplied with 30 feet (10 mts) 4mm sq. insulated copper cable is used to connect measuring unit.

Dimensions
38mm OD x 150mm long (1.5 x 6 long)
21 Oz (600gms)

Stability
< ± 5mv

Operating Temperature
0-50º C

Certification
Each cell is tested and provided with batch test certificate.

Typical Applications
cathodic protection experts can now measure the electrical potentials for offshore, sea water, rivers, elevated water tanks, stand pipes, ground storage tanks, clarifiers, traveling screens, trash racks, submerged pipelines, locks, dams, dock.

Safety
Material safety data sheet also available on request.

Shipping
Reference cells are shipped quickly based on quantity ordered

In India, we have various customers from Mumbai, Delhi, Bangalore, Chennai, Hyderabad, Ahmedabad, Kolkata, Surat, Pune, Jaipur, Lucknow, Kanpur, Nagpur, Visakhapatnam, Indore, Bhopal, Patna, Vadodara, Ghaziabad, Ludhiana, Coimbatore, Madurai, Nashik, Srinagar, Aurangabad, Dhanbad, Allahabad and Ranchi in India.



Engineered for Harsh Environments

Built with a high impact PVC body and IP68 rating, the Fontana 103 reference cell is designed for permanent installation in underground or submerged environments. Its sturdy construction allows it to operate effectively in a wide temperature range of -10C to +60C and withstand humidity up to 95%, making it suitable for diverse climatic conditions in India.


Reliable Long-Term Monitoring

The special formulated electrolyte offers exceptional ionic conductivity, ensuring stable and precise readings for cathodic protection systems. With an adjustable electrode area and negligible power consumption, this maintenance-free cell supports continuous monitoring, reducing operational effort and cost over time.

FAQs of Permanent Reference Cells - Fontana 103 Ag/agcl:


Q: How is the Fontana 103 Ag/AgCl Permanent Reference Cell installed?

A: The cell is designed for direct burial in backfill or soil or submersion in water. Simply connect the copper lead wire to your cathodic protection system, position the cell in the desired location, and cover as required. Detailed installation instructions are included in the package.

Q: What is the measurement range and accuracy of this reference cell?

A: The Fontana 103 measures potentials in the range of -1200 mV to +1200 mV with a high resolution of 1 mV and an accuracy of 10 mV, ensuring reliable data for cathodic protection monitoring.

Q: When should I use a permanent reference cell like the Fontana 103?

A: This reference cell is ideal for applications requiring continuous, long-term cathodic protection monitoring in underground or underwater installations, such as pipelines, storage tanks, and marine structures.

Q: Where can the Fontana 103 reference cell be deployed?

A: It can be installed underground in soil or backfill, or underwater in environments where IP68 protection is essential. Its physical and environmental resilience makes it suitable across multiple terrains and conditions.

Q: What are the benefits of using the Fontana 103 for cathodic protection monitoring?

A: Key advantages include maintenance-free operation, high measurement accuracy, robust construction, and stability in harsh or variable environments, leading to lower maintenance costs and assured protection monitoring.

Q: Is any maintenance required for the Fontana 103 reference cell?

A: No routine maintenance is needed. The cell is designed to operate reliably throughout its service life without requiring upkeep, as long as it is installed and used according to the manufacturers instructions.

Q: What process ensures the accuracy and reliability of this reference cell?

A: The combination of a silver/silver chloride sensing element, special formulated electrolyte, and stable high impact PVC body ensures both long-term precision and minimal drift, even in demanding underground or submerged conditions.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Reference Electrodes Category

Portable Half Cell - Sc-4 Ag/agcl

Portable Half Cell - Sc-4 Ag/agcl

Price 50 INR / Unit

Minimum Order Quantity : 1 Unit

Diameter : 40 mm (approx.)

Power Supply : Battery powered (typically 9V battery)

Application Media : Concrete, soil, water

Protection : Shockresistant casing

Portable Reference Cells - Fontana 101f Cu-cuso4

Portable Reference Cells - Fontana 101f Cu-cuso4

Price 50 INR / Unit

Minimum Order Quantity : 1 Unit

Diameter : About 35 mm

Power Supply : Not Required (Passive Device)

Application Media : Electrochemical, Cathodic Protection, Corrosion Monitoring

Protection : Rugged, Leak Proof Body

Cp Half Cell Cu/cuso4

Cp Half Cell Cu/cuso4

Price 50 INR / Unit

Minimum Order Quantity : 1 Unit

Diameter : Approx. 22 mm

Power Supply : Not Applicable (Passive device)

Application Media : Soil, Water, Concrete

Protection : PVC or ABS Casing for Chemical Resistance

Permanent Reference Cell - Fontana 104C Cu-CuSO4

Permanent Reference Cell - Fontana 104C Cu-CuSO4

Price 50.0 INR / Piece

Minimum Order Quantity : 1 Piece

Diameter : 34 mm

Power Supply : Not applicable (Passive reference cell)

Application Media : Soil, buried pipelines, tanks, concrete structures

Protection : Durable, leakproof body



Back to top