Automatic Flash Point Tester Specification

  • Resolution
  • 0.1C
  • Pressure Range
  • Atmospheric
  • Capacity
  • Test Cup 50 ml
  • Current Range
  • Up to 2A
  • Application Media
  • Petroleum and Chemical Products
  • Equipment Type
  • Automatic Flash Point Tester
  • Connectivity Type
  • RS232 / USB
  • Sensor Type
  • Platinum Resistance Temperature Detector (RTD)
  • Humidity %
  • 10% to 80% RH
  • Measurement Range
  • 50C to 400C
  • Temperature Range
  • Ambient to 400C
  • Protection
  • Over-Temperature and Over-Current Protection
  • Diameter
  • 50 mm Test Cup
  • Frequency
  • 50 Hz
  • Material
  • Stainless Steel
  • Power Supply
  • 230V AC, 50Hz
  • Power Consumption
  • 100W
  • Accuracy
  • 1C
  • Display Type
  • Digital LCD Display
  • Range
  • Ambient to 400C
 

Automatic Flash Point Tester Trade Information

  • Minimum Order Quantity
  • 50 Pieces
  • Supply Ability
  • 500 Pieces Per Day
  • Delivery Time
  • 1 Week
 

About Automatic Flash Point Tester

Technical Specification

  • Power supplyAC 220 V10%50Hz
  • Thermometer : 0400 each scale division is 0.1 .
  • Ambient temperature 35
  • Relative humidity85
  • Total power consumptionless than 700 W
  • With accessional printer





Precision and Reliability for Laboratory Testing

This automatic flash point tester is equipped with a platinum RTD sensor and achieves an accuracy of 1C, providing confidence in every test run. Programmable settings, a wide measurement range (50C to 400C), and versatile test methods enable users to carry out tasks efficiently while maintaining strict compliance with ASTM D93 and ISO 2719 standards.


Advanced Safety and User-Friendly Operation

Safety is built-in, with features like automatic shutoff upon overheating and robust over-current protection. The fully automatic operation streamlines the testing process, allowing users to run tests with minimal intervention. The digital LCD display guides users through programmable sequences, ensuring both ease of use and consistent quality results.

FAQs of Automatic Flash Point Tester:


Q: How does the automatic flash point tester ensure accuracy during testing?

A: This tester uses a platinum resistance temperature detector (RTD) sensor, combined with programmable heating and stirring, to deliver highly accurate results (1C). The photoelectric sensor detects the flash point reliably, while automated calibration through software further boosts measurement precision.

Q: What types of samples and test methods can be used with this equipment?

A: The device is designed for petroleum and chemical products, accommodating test cups of 50 mm diameter and 50 ml capacity. It supports both Pensky-Martens and Cleveland Open Cup flash point methodologies, offering flexibility in laboratory applications.

Q: When should the safety features like automatic shutoff be expected to activate?

A: The automatic shutoff mechanism engages if the instrument detects overheating or excess current, thereby protecting both the user and equipment. This ensures safe operation throughout the testing process, even during prolonged or unattended runs.

Q: Where can the flash point tester be installed and operated efficiently?

A: The compact dimensions (380 x 320 x 360 mm) and robust stainless steel construction allow installation in laboratories, quality control rooms, or testing facilities. It operates effectively in ambient conditions ranging from 0C to 40C with humidity levels between 10% and 80% RH.

Q: What is the process for connecting this tester to a computer or data system?

A: The tester features USB and RS232 interfaces for seamless PC connectivity, enabling direct data transfer and integration with laboratory information systems. Simply connect using the appropriate cable and utilize the included software for calibration, test management, and data analysis.

Q: How user-friendly is the day-to-day operation of this equipment?

A: Operation is straightforward due to its fully-automatic sequence, programmable settings, and digital LCD display. The automatic motorized stirrer and software-assisted calibration reduce manual workload, making daily tasks both efficient and reliable.

Q: What are the key benefits of using this automatic flash point tester in a laboratory setting?

A: Key advantages include consistent high-accuracy measurements, compliance with international standards, enhanced safety mechanisms, ease of use through automation, and versatile connectivity for efficient data management. These features make it an essential tool for dealers, manufacturers, and laboratories involved in petroleum and chemical analysis.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Performance Category

Flash Point Tester

Flash Point Tester

Price 50 INR / Piece

Minimum Order Quantity : 50 Pieces

Display Type : Other, Digital LED Display

Accuracy : 1C

Material : Stainless Steel (SS) body with heatresistant parts

Power Supply : 230V 10%, 50Hz AC

Table Ph Meter

Table Ph Meter

Price 50 INR / Unit

Minimum Order Quantity : 1 Unit

Display Type : Other, Digital LED Display

Accuracy : 0.01 pH

Material : ABS Plastic (Body)

Power Supply : AC 220V 50Hz

Minimum Film Forming Temperature Tester (Mfft Tester)

Minimum Film Forming Temperature Tester (Mfft Tester)

Price 50 INR / Unit

Minimum Order Quantity : 1 Unit

Display Type : Other, Digital Display

Accuracy : 0.1C

Material : Stainless Steel Body

Power Supply : 220V AC, 50Hz

Fineness of Grind Gauges

Fineness of Grind Gauges

Price 50 INR / Piece

Minimum Order Quantity : 50 Pieces

Display Type : Other, Engraved Graduated Scale

Accuracy : 1 m

Material : HighGrade Hardened Stainless Steel

Power Supply : Manual (NonElectric)