Flash Point Tester Specification

  • Application Media
  • Oil, Petroleum Products
  • Capacity
  • Test cup capacity: 75 ml
  • Equipment Type
  • Flash Point Tester
  • Measurement Range
  • Up to 300C
  • Sensor Type
  • PT100 temperature sensor
  • Protection
  • Over temperature and electrical protection
  • Diameter
  • Test cup: 50 mm (approx.)
  • Connectivity Type
  • None/Manual Operation
  • Temperature Range
  • Ambient to 300C
  • Frequency
  • 50 Hz
  • Resolution
  • 0.1C
  • Pressure Range
  • Atmospheric
  • Humidity %
  • Up to 85% RH
  • Material
  • Stainless Steel (SS) body with heat-resistant parts
  • Power Supply
  • 230V 10%, 50Hz AC
  • Power Consumption
  • 50 W
  • Accuracy
  • 1C
  • Display Type
  • Digital LED Display
  • Range
  • Ambient to 300C
  • Equipment Type
  • Closed Cup Flash Point Tester
  • Sample Quantity
  • 50 ml 75 ml per test
  • Cooling System
  • Natural/Optional Water Bath
  • Dimensions (LxWxH)
  • Approx. 300 x 200 x 250 mm
  • Safety Feature
  • Automatic shut-off in case of overheating
  • Weight
  • Approx. 6-8 kg
  • Heating Rate
  • As per IS/ASTM Standards
  • Ignition Source
  • Electric/Flame, supplied with the unit
  • Operation Type
  • Manual/ Semi-automatic
  • Accessory
  • Test cup, lid, thermometer, ignition system included
 

Flash Point Tester Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 500 Pieces Per Day
  • Delivery Time
  • 1 Week
 

Flash Point Tester About

Technical Specification

Power supplyAC 220 V1050Hz

Thermometer 0400 

Ambient temperature 35 

Relative humidity 85

Total power consumptionless than 650 W




Precision and Safety in Flash Point Testing

This Flash Point Tester stands out for its exceptional accuracy (1C) and comprehensive safety. It utilizes a PT100 temperature sensor and offers both electric and flame ignition sources to meet diverse requirements. With a robust stainless steel construction and over-temperature as well as electrical protection, users can confidently conduct tests, minimizing risk while maximizing efficiency for oil and petroleum analysis.


Adaptable Operation and Versatile Cooling

Designed for both manual and semi-automatic processes, this tester accommodates different user preferences and laboratory protocols. The natural cooling system can be optionally enhanced with a water bath, enhancing versatility for repeated or continuous use. Its compact dimensions and manageable weight allow for easy integration into any laboratory setup.

FAQs of Flash Point Tester:


Q: How does the automatic shut-off safety feature of the Flash Point Tester work?

A: The automatic shut-off safety feature detects overheating and immediately powers down the heating element, preventing damage to the tester and ensuring user safety. This system complies with stringent safety standards typically required in laboratory environments.

Q: What media and sample types can be tested with this Flash Point Tester?

A: This tester is specifically designed for oil and petroleum products, making it suitable for laboratories, refineries, and quality control settings. The test cup holds 50 to 75 ml per sample, adhering to standard test procedures.

Q: When should I use the electric versus the flame ignition source?

A: The electric ignition source is preferable for precise, repeatable results and when flammable vapors are a concern. The flame ignition is useful for comparison studies or when specified by particular IS or ASTM methods. Both options are supplied with the unit.

Q: Where can this Flash Point Tester be used effectively?

A: The testers compact size and robust design allow installation in laboratories, research facilities, oil and petroleum product testing centers, and quality assurance departments. Its portability suits both permanent and temporary lab setups.

Q: What is the process for conducting a flash point test using this equipment?

A: Begin by pouring 5075 ml of sample into the test cup. Insert the supplied thermometer and close the lid. Set the desired heating rate as per IS/ASTM standards, select the ignition source, and start the test. The digital LED display provides precise readings, and the tester automatically warns or shuts off in case of overheating.

Q: How does the cooling system function, and is water cooling necessary?

A: The instrument uses a natural cooling system which sufficiently aids most standard tests. However, for frequent or high-throughput testing, an optional water bath can be installed to ensure rapid cooldown cycles and maintain accuracy.

Q: What are the key benefits of using this Closed Cup Flash Point Tester?

A: Users benefit from accurate, reproducible results; robust safety features; compatibility with international testing standards; and flexibility for both manual and semi-automatic operation. The supplied accessories and user-friendly interface create an efficient, dependable testing process for various oil and petroleum products.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Performance Category

Line Drying Time Recorder

Line Drying Time Recorder

Price 850.0 INR / Piece

Minimum Order Quantity : 1 Piece

Display Type : Other, Analog

Temperature Range : 10C to 40C

Range : 0 to 24 hours

Material : Mild Steel with Powder Coating

Table Ph Meter

Table Ph Meter

Price 50 INR / Unit

Minimum Order Quantity : 1 Unit

Display Type : Other, Digital LED Display

Temperature Range : 0C to 60C

Range : 0.00 ~ 14.00 pH

Material : ABS Plastic (Body)

Minimum Film Forming Temperature Tester (Mfft Tester)

Minimum Film Forming Temperature Tester (Mfft Tester)

Price 50 INR / Unit

Minimum Order Quantity : 1 Unit

Display Type : Other, Digital Display

Temperature Range : 0C to 50C

Range : 0C to 50C

Material : Stainless Steel Body

Fineness of Grind Gauge

Fineness of Grind Gauge

Price 170.0 INR / Unit

Minimum Order Quantity : 1 Unit

Display Type : Other, Engraved Scale

Temperature Range : Ambient

Range : 0 to 25 microns (Hegman Scale: 8 to 0)

Material : Stainless Steel or Hardened Alloy



Back to top